|
|
|
ABSTRACT |
The aim of this study is to compare the relation between ventilation (VE) and oxygen uptake (VO2) [VO2=Æ’(VE)] and between heart rate (HR) and VO2 [VO2=Æ’(HR)]. Each one of the subjects performed three types of activities of different intensities (walking without load, walking with load and intermittent work). VO2, VE, and HR were measured continuously by using indirect calorimetry and an electrocardiogram. Linear regressions and coefficients of determination (r2) were calculated to compare the relation VO2 =Æ’(VE) and VO2 =Æ’(HR) for two different regroupings: by session duration (r2session) and by subject (r2subject). Results showed that r2session of the relation VO2 =Æ’(VE) were significantly higher than those of the relation VO2 =Æ’(HR) for steady state activities (walking with or without load during 3 or 6 min, p < 0.01) and for activities without oxygen consumption steady state (walking with or without load during 1 min, p < 0.01 and intermittent work, p < 0.05). VE is more strongly correlated with VO2 than with HR. This is a very promising approach to develop a new method to estimate energy expenditure. |
Key words:
Physical activities, light to moderate intensities, steady state activities, non-steady state activities.
|
Key
Points
- Ventilation is more strongly correlated with oxygen uptake than heart rate during physical activities of different intensities.
- This study shows the interest to looking for ventilation to estimate energy expenditure.
- This study is a promising approach to develop a new method to estimate energy expenditure
- An interesting perspective could be to develop a light and portable device to measure ventilation based on the coupling of four magnetometers.
|
Physical activity represents the most variable part of the human energy expenditure (EE) (Ravussin and Gautier, 2002). The accurate measurement of EE associated with physical activity remains a difficult challenge. This difficulty increases when we look at light or intermittent activities. Many parameters have been explored to estimate EE, during physical activities of different intensities. Doubly labelled water (DLW) and indirect calorimetry techniques, considered as the gold standard measures of EE (Westerterp, 1999), are both limited in their assessment of free-living EE. Indirect calorimetry cannot assess free- living subjects easily, whereas DLW does not provide information on the pattern, frequency, or intensity of physical activity. Portable and less costly devices are emerging and also making it possible to estimate EE in free-living conditions. Electronic motion sensors attempt to analyze the movements of the human body in order to estimate “counts” and TEE (Total Energy Expenditure) (Bouchard and Trudeau, 2008; Corder et al., 2007; Nilsson et al., 2008; Plasqui and Westerterp, 2007). Unfortunately, they are unable to detect arm movements, or external work done in lifting or pushing objects, which may represent a considerable component of lifestyle activity (Bassett et al., 2000). New portable devices are able to couple biomechanical and physiological parameters. The Actiheart®and the SensorWear Armband® coupled the measurement of physiological parameters (heart rate and heat flow respectively) with an accelerometer system. These devices provide better results compared to the classic electronic motion sensors, but differences are still measured in comparison with reference methods (Brage et al., 2005; Corder et al., 2005; Fruin and Rankin, 2004; King et al., 2004). To consider EE under free-living conditions, one of the most current approaches in the field of physiology, consists in using the relation between heart rate (HR) and oxygen uptake (VO2) (VO2 = (HR × Ves) × (CaO2 - C v O2)), where Ves represents the volume of systolic ejection (ml·min-1), CaO2 is the amount of oxygen carried by arterial blood (ml·100ml-1), and C v O2 is the amount of oxygen carried by venous blood (ml·100ml-1). This method has been largely studied (Garet et al., 2005; Hiilloskorpi et al., 2003; Kurpad et al., 2006; Livingstone et al., 2000; Rayson et al., 1995) and proved to be adapted to estimate EE: the cardiofrequencemeter is an easily portable device that does not present any invasive character. Nevertheless, the use of HR to consider EE can be criticized because of the variability of this parameter during activities of low and very high intensities (Achten and Jeukendrup, 2003; Haskell et al., 1993). In the same way, many other studies (Davidson et al., 1997; Melanson and Freedson, 1996; Montoye et al., 1996) have showed that emotional stress, high ambient temperature, high degrees of humidity, dehydration, body posture, or disease may imply HR variations without any VO2 variation. All these limits account for the difficulties of measuring a precise EE from HR measurements particularly during light physical activities. Therefore, we propose to explore another physiological parameter, complementary to HR, which is also in strong relation with VO2 and EE. Ventilatory output or ventilation (VE) also varies during physical activity (Saltin and Astrand, 1967; Wasserman et al., 1986) and two studies suggest that pulmonary ventilation (VE) could be an index of EE (Durnin and Edwards, 1955; Ford and Hellerstein, 1959). Indeed, VE is a parameter directly related to oxygen consumption (VO2 = VE × [FiO2 - FeO2], where FiO2 represents the fractional concentration of O2 in inspired air and FeO2 is the fractional concentration of O2 in expired air) and thus indirectly with EE (Saltin and Astrand, 1967). VE is especially interesting because Durnin and Edwards report that, during light and moderate exercise, when VE is less than 50 l·min-1, VO2 of any one individual is directly proportional to his VE. Furthermore, VE does not necessarily require the use of a facial mask to be measured. McCool et al., 2002 in this case proposed a light and portable system to measure VE based on four coupled magnetometers. This system, compared with the measurement carried out by spirometry, enables a precise measurement of tidal volume (VT), inspiratory (TI), and expiratory time (TE) in sitting and standing positions and exercise conditions. Taking into consideration this new technology, it may now be possible to use VE to estimate EE. Such an approach may therefore provide new prospects in EE estimation, compared with the limitations of HR measurements. Nevertheless, it may be questioned as to which of the two parameters VE or HR is better correlated with VO2. The purpose of this methodological study is to answer this question during physical activities of different intensities. Then, we postulate the following hypothesis: during physical activities of different intensities VE is more strongly correlated with VO2 than HR. To validate our assumption, we compared the relations VO2 = Æ’ (HR) and VO2 = Æ’ (VE) during varied sequences of walking with and without load and intermittent work. The interest of this work is to compare the parameters VE and HR as an indicator of VO2 and to show the interest of VE to estimate EE. Moreover, it is important to note that this is the first study who choose to compare the two relationship, VO2 = Æ’ (HR) and VO2 = Æ’ (VE), during physical activities of different intensities.
SubjectsTwelve healthy males, aged 27.25 ± 4.33 years, voluntarily took part in this study. The mean values and standard errors of their physical characteristics, maximal oxygen uptake (VO2max), and ventilatory threshold (VT) are shown in Table 1. This study was conducted according to the guidelines laid down in the Declaration of Helsinki and all procedures involving human subjects were approved by the local ethics committee of the University of Rennes 1. Written informed consent was obtained from all subjects. None of the subjects reported respiratory or cardiac disease, hypertension, or was known to be suffering from any other chronic disease.
Experiment designThe experimental protocol is schematized in Figure 1. The first day of experiments (D1) was devoted to laboratory testing, including anthropometric and body composition measures. Each subject performed a maximal increment exercise test on the treadmill in order to appreciate the relative intensities of each exercise carried-out on D2, D3 or D4. A warm-up session was carried out for 10 min at 8 km·h-1. The test started at an initial 10 km·h-1. The incrementation of the test was 1 km·h-1 every 3 min. The subjects were verbally encouraged to continue their efforts. It was estimated that the subjects had reached their VO2max when three or more of the following criteria were met; a steady state of VO2 despite increasing running speed (change in VO2 at VO2max < 150 ml·min-1 ) (Taylor et al., 1955), a final respiratory exchange ratio (Rmax) higher than 1.1, a visible exhaustion and a HR at the end of the exercise (HRmax) within the 10 bpm of the predicted maximum [210 - (.65 × age); (Spiro, 1977)]. During the following three days (D2, D3, and D4) each of the subjects performed three different types of activities (walking without load, walking with load, intermittent work) over three distinct days. A period of 48 hours separated each activity. These activities were carried out randomly by each subject. Each day was initialized by 5 min of rest in a sitting position. All these activities were carried out on a treadmill (Gymrol, super 2500). The first activity consisted in walking without load. Each subject carried out three sessions of walking (3, 4.5, and 6 km·h-1), the order being self-selected by the subject. Thereafter, each walking session was characterized by a time duration (1, 3, or 6 min) and a slope (0, 5, or 10 %) also self-selected by the subject. The detail of the walking session with and without load is presented in Figure 2. One 10-min period of rest (seated) was maintained between each session of walking. The second activity was walking with a load. The protocol was the same as that for walking without a load. The load applied to the subject was a backpack stuffed with 10 kg. The load was applied to the subject at the last minute, right before starting the walking session. During periods of rest and between the various steps, the backpack was removed from the subject. Finally, the third activity was intermittent work. This session consisted in alternating walking (5 km·h-1) and running (10 km·h-1) sequences. A session consisted of five consecutive sequences where the duration of each period of walking and running was chosen at random by the subject (30, 45, or 60 s). The whole range of activities was carried out under ambient controlled conditions. For all activities, participants were asked to refrain from physical activity, medicine, alcohol, and tobacco 24 h before testing and to refrain from food 2 h beforehand. The Subjects were asked to arrive at the laboratory 30 min before the beginning of the measurements. On D1, measurements (VO2, VE, and HR) started at the beginning of the warm-up period. On D2, D3, and D4, the measurements started at the beginning of the sitting position period of 5 min.
Gas exchange and heart rate measurementsBreath-by-breath measurements of gas exchange were made using the MetaLyser 3B®(Cortex Biophysic, Leipzig, Germany). Expiratory airflow was measured with a volume transducer (Triple V® turbine, digital) connected to an O2 analyser. Expired gases were analysed for oxygen (O2) with electrochemical cells and for carbon dioxide (CO2) output with the ND infrared analyser. Before each test, the MetaLyser 3B® was calibrated according to manufacturers’ guidelines. After a 60-min warm-up period, the CO2 and O2 analysers were calibrated against room air as well as a reference gas of known composition (5% CO2, 15% O2, and 80% N2), and the volume was calibrated by five inspiratory and expiratory strokes with a 3-litre pump. Oxygen uptake (VO2) and ventilation (VE) were measured and displayed continuously on the computer screen. The electrocardiogram (Delmar Reynolds Medical®, CardioCollect 12) was also continuously monitored at both restful and active periods. Heart rate was derived from the R-R interval of the ECG. The ECG tracing was continuously displayed on the computer screen. The entire data (VO2, VE, and HR) during each breath was calculated, and the sampled data transferred breath-by-breath to a PC for immediate display. The recorded data was saved in the internal database of MetaSoft® for a precise performance analysis after the test. The data of VO2, VE and HR was averaged every 5 s for statistical analysis.
Determination of ventilatory threshold (VT)VT was determined on D1 during the maximal incremental exercise test. To determine VT for each subject, we used the criteria of Wasserman (Wasserman et al., 1990): the threshold corresponds to the breakpoint in the VE / VO2 relationship, whereas the relationship VE / VCO2 remains stable. VT was determined visually by two independent investigators.
Session intensity calculationTo evaluate the intensity of each session, we chose to express it as the mean value of VO2 and as a percentage of VO2max. The mean value of VO2 was calculated over the total time of each session. These individual values of VO2 were then averaged to obtain VO2mean and the percentage of VO2max for each activity group (Table 2). The mean value of VE and HR were also calculated over the total time of each session. These individual values of VE and HR were then averaged to obtain VEmean and HRmean.
Session distribution of activities at various intensities within four principal groupsEighty-four sessions were programmed as each subject had to carry out seven activity sessions (three walking activities without load + three walking activities with load + one intermittent work). Nevertheless, four of the sessions were not taken into account, as four of the walking activities of two subjects were removed because of errors of measurement. Therefore the full number of sessions included in this study was 80. In order to analyse the results, the whole range of activities was classified into two different parts. Each part was devised into two different groups. This classification was carried out in accordance with the duration of each activity (Table 2). - The part 1 includes activities with oxygen consumption steady state. The first group (Group 1) incorporated walking activities with or without load (n=20) for a duration of 3 min and at an intensity including between 20 and 55% of VO2max. The second group (Group 2) incorporated walking sessions with or without load (n=26) for a duration of 6 min and at an intensity including between 17 and 62 % of VO2max. - The part 2 includes activities without oxygen consumption steady state. The third group (Group 3) incorporated walking activities with or without load (n = 22) at a duration of 1 min and with an intensity including between 13 and 40% of VO2max. Finally, the fourth group (Group 4) is made up of the intermittent work (n = 12) with an intensity including between 40 and 60% of VO2max.
Coefficients of determination calculationTo confirm our hypothesis (that VE is more strongly correlated with VO2 than HR), we proposed to compare the relations VO2 =Æ’(HR) and VO2 =Æ’(VE) during varied sessions of activities, using the coefficients of determination (r2). The r2 were calculated by combining the whole of the activities in two different ways. Firstly, for all of the activity sessions (n=80), a linear regression was established between parameters VO2 and VE and between VO2 and HR (n = 160 regressions). The r2 was calculated over the total time of each session (r2session). For the four different groups, all of the individual values of r2session were averaged out and are reported in Table 2. Secondly, for each subject (n = 12), the data sets of VO2, VE and HR of the seven individual sessions were incorporated. From the value sets of each subject, a linear regression was established between VO2 and VE and VO2 and HR (n = 24 regressions). The r2 was calculated over the total time of the seven individual sessions of each subject (r2subject). The r2subject is reported in Table 3.
Statistical analysisWe used the Mann Whitney test to calculate the level of significance of the correlations and to specify if there exists a significant difference between the r2session from the relations VO2 = Æ’ (HR) and VO2 = Æ’(VE) of each group of activities. The same test was applied to calculate the level of significance of the average values of r2subject. Values of p < 0.05 were considered significant.
Coefficient of determination from the four different groups of activities ( and )The mean values of the r2session from the relations VO2 = Æ’ (HR) and VO2 = Æ’(VE) for the four different groups of activities are represented in Table 2. The r2session of the linear regressions from the relation VO2 = Æ’ (VE) were significantly higher than those obtained from the relation VO2 = Æ’(HR) for the first (walking exercise with and without load, between 20 and 55% of VO2max and for a duration of 3 min, p < 0.01), second (walking exercise with and without load, between 17 and 62% of VO2max and for a duration of 6 min, p < 0.01), third (walking exercise with and without load, between 13 and 40% of VO2max and for a duration of 1 min, p < 0.01) and the fourth group of activities (intermittent work, between 40 and 60 % of VO2max, p < 0.05). Figure 3 shows the linear regression from the relations VO2 = Æ’ (VE) and VO2 = Æ’ (HR) for the four different groups of activities. The graphs joined the whole of data of each group of activities (n = 750, n = 1907, n = 295 and n = 1140 for the group 1, 2, 3 and 4 respectively). The standard error of estimate (SEE) was calculated and mentioned on each graph.
Coefficient of determination, by subject, over the total duration of the seven sessions ()The individual values of the r2subject from the relations VO2= Æ’(HR) and VO2= Æ’ (VE) are represented in Table 3. The r2subject of the linear regressions from the relation VO2= Æ’ (VE) is always higher than those from the relation VO2= Æ’ (HR), except for the subject 2 and 3. The mean value of r2subject of the linear regression from the relation VO2 = Æ’ (VE) was significantly higher than that obtained from the relation VO2 = Æ’ (HR) (p<0.05).
The aim of this study was to compare the relation between VO2 = Æ’(VE) and VO2 = Æ’(HR) during physical activities of different intensities: walking with or without load, with or without slope during various durations and alternating between different periods of walking and running (Ainsworth et al., 2000). We chose to apply a load of 10 kg to each subject because this weight could correspond to individuals who use a backpack to carry books, computers in free-living conditions. So, we have chosen our exercise protocol because the daily life is characterized by light and moderate activities, carried out in a random order during short durations (Ainsworth et al., 2000). For this reason the walking activities with and without load were characterized by duration and slope self-selected by the subject. The same reasons led us to characterize intermittent work by random duration. The intensity of each walking exercise and intermittent work was defined from VO2mean calculated on the total time of exercise. This methodology has been observed for all durations of exercise (1min, 3min, 6min and intermittent work). The calculation of VO2mean is coherent with the calculation of the coefficient of determination carried out for each exercise (taking into account the total time of each exercise). However, this approach has constrained us to divide the exercises into two groups. The first group consisted of exercises performed with a VO2 steady state (walking during 3 and 6 min). The on-transient and steady state period are taken into account to calculated VO2mean. The second group consisted of exercises without oxygen consumption steady state (walking during 1 min and intermittent work). The whole of the variation of VO2 are taken into account to calculated VO2mean. This calculation is an estimate of exercise intensity. Lastly, we did not seek to calculate the intensity of each walk and each run of the intermittent work. The range of values of the coefficients of determination (r2session, r2subject) shows that VE is more strongly correlated with VO2 than HR (Table 2 and Table 3). The mean intensities of the sessions are included between 24.2 and 47.08% of VO2max. A light intensity exercise is usually considered at a level between 1 to 3 METs or lower to 45% of VO2max, and a moderate intensity exercise between 3 to 6 METs or lower to 60% of VO2max (Friedlander et al., 2007; Smith and Morris, 1992; Swain and Franklin, 2006). Hence, the results of the study confirm the hypothesis initially posed. Moreover, it is the first study that shows that VE is more strongly correlated with VO2 than HR and especially during activities of light to moderate intensities. To validate our assumption, we chose to characterize the relations VO2 = Æ’ (VE) and VO2 = f (HR) by a linear regression. In 1967, Saltin and Astrand showed that during an incremental exercise, the increase of VE in relation to VO2 is semi-linear, the progression of VE becoming relatively more important than VO2 when the exercise intensities become vigorous. An exponential increase is observed for vigorous intensities of exercises, which are higher than 65% of VO2max. Davis et al. from ventilation criteria observed in subjects, aged 30 years, values of VT of 58.6 ± 5.8% (mean ± SD) of VO2max during a treadmill exercise (Davis et al., 1976). In this study, the intensities of each session of the subjects remain lower than 65% of VO2max. Moreover, the mean intensities of the whole sessions carried out by the subjects are close to than their VT (VTmean = 48 ± 4.53% (mean ± SD) of VO2max). Therefore, the values of VE and VO2 remain located in the linear part of the curve. These values of VE are consistent with the study of Durnin and Edwards who report that, when VE is less than 50 l·min-1, VO2 of any one individual is directly proportional to his VE. Indeed, the VE values are 30.25 l·min-1 (±10.22), 30.69 l·min-1 (± 12.27), 23.64 l·min-1 (± 6.53) and 46.03 l·min-1 (± 4.74) for the groups 1, 2, 3 and 4, respectively. The relation VO2 = Æ’ (HR) is also characterized by a linear relation. This relation is widely accepted for a physical exercise which is progressive, involves important muscular masses, and is long enough to allow adaptation of the cardiovascular and ventilatory systems (Astrand and Ryhming, 1954). Thus, a linear relation exists for a broad range of exercise intensities (classically from 30% to 70% of VO2max), such as those presented in this study (from 24.2 to 47.08% of VO2max). Thus, the values of HR and VO2 remain located in the linear part of the curve. Nevertheless, during light and very highly intense activity, this relation becomes non-linear (Achten and Jeukendrup, 2003). To compare our results with other studies (Durnin and Edwards, 1955; Ford and Hellerstein, 1959; Livingstone, Robson, 2006; Spurr et al., 1988), we have, in accordance with these studies, chosen a linear regression to compare the two relations VO2 = Æ’ (VE) and VO2 = Æ’ (HR), for the whole sessions carried out with the subjects in this study. The most interesting result of this study is that r2session of the relation VO2 = Æ’(VE) is significantly higher than the r2session of the relation VO2 = Æ’ (HR) for groups 1, 2, 3 and 4 (Table 2). Moreover, this result is observed during exercise with oxygen consumption steady state (walking with or without load during 3 or 6 min), and during exercise without oxygen consumption steady state (walking with or without load during 1 min or intermittent work). Another interesting result is observed when the sets of measures of the sessions carried-out by each subject are joined together (walking with and without loads, intermittent work). For 10 of the 12 subjects, the coefficient of determination r2subject of the relation VO2 = Æ’ (VE) is higher than the r2subject of the relation VO2 = Æ’ (HR) (Table 3). Moreover, the mean coefficient of the relation VO2 = Æ’ (VE) is significantly higher than the mean coefficient of the relation VO2 = Æ’ (HR). The differences among r2session and r2subjects from the relations VO2 = Æ’ (VE) and VO2 = Æ’(HR) may be explained by the different mechanisms of control of VE and HR (Strange et al., 1993; Whipp and Ward, 1982). To date, no study has been able to predict, on a strictly physiological level, the preferential interest in using HR compared with VE to estimate VO2. Nevertheless, many arguments previously mentioned imply that VE seems to be a parameter much better correlated with VO2 than HR, in particular during physical activities of different intensities. Hence, it is legitimate to think that a relation between VE and VO2 could be established to estimate EE starting only from the measurement of VE. It is interesting to develop a new device to measure the VE of a subject in a non-invasive way. This innovation would make it possible to measure VE in daily life conditions (light to moderate intensities). It is currently possible to precisely measure VT, TI, and TE and to calculate VE, thanks to a non-invasive device using magnetometry (McCool et al., 2002). We currently develop a light and portable device allowing the direct measurement of VE based on the coupling of four magnetometers. This device has no invasive character and could quickly be used to estimate EE under free-living conditions. Furthermore, new portable devices (Actiheart and SensorWear Armband) demonstrate the added value of combining several parameters, and represent certainly the future solutions to estimate EE in free living condition. From this model, it would be possible to couple HR to another physiological parameter to overcome the difficulties of the HR method to estimate EE during low levels of activity. So, VE would estimate EE during light and moderate activity, and HR would be a complementary parameter to improve the estimation of EE during moderate activity requesting important muscular masses. It would be necessary to integrate this system into clothing (shirt or vest) to make it possible to process measurements under daily life circumstances.
This study shows that VE is more strongly correlated with VO2 than HR during physical activities of different intensities. This result confirms the interest to looking for VE to estimate EE.
ACKNOWLEDGEMENTS |
The authors wish to acknowledge all the subjects for their participation in the study. This study was funded through the SVP (“SurVeiller pour Prévenir”) project. There is no conflict of interest in this research. The five authors have participated in the development and implementation of the protocol and to write this article. |
|
AUTHOR BIOGRAPHY |
|
Steven Gastinger |
Employment: PhD Student at the Department of Sport Sciences, Rennes 2 University, France. |
Degree: MSc. |
Research interests: Quantification of physical activities, estimation of energy expenditure, development of a new portable device to measure ventilation. |
E-mail: gastingersteven@yahoo.fr |
|
|
Anthony Sorel |
Employment: PhD Student at the Department of Sport Sciences, Rennes 2 University, France. |
Degree: MSc. |
Research interests: Biomechanics, quantification of physical activities, motion analysis, motion recognition, virtual reality. |
E-mail: anthony.sorel@univ-rennes2.fr |
|
|
Guillaume Nicolas |
Employment: Lecturer at the Department of Sport Sciences, Rennes 2 University, France. |
Degree: MSc, PhD. |
Research interests: Biomechanics, motion analysis / simulation, quantification of physical activity, bipedal locomotion, swimming. |
E-mail: guillaume.nicolas@univ-rennes2.fr |
|
|
Arlette Gratas-Delamarche |
Employment: Professor at the Department of Sport Sciences, Rennes 2 University, France. |
Degree: PhD and authorize to supervise research. |
Research interests: Oxidative stress, metabolic diseases, beneficial effect of physical activity on health. |
E-mail: arlette.delamarche@univ-rennes2.fr |
|
|
Jacques Prioux |
Employment: Professor at the ENS Cachan, Antenne de Bretagne, France. |
Degree: PhD and authorize to supervise research. |
Research interests: Quantification of physical activities, estimation of energy expenditure, ventilatory response to exercise, training and intermittent work. |
E-mail: jacques.prioux@bretagne.ens-cachan.fr |
|
|
|
REFERENCES |
Achten J., Jeukendrup A.E. (2003) Heart rate monitoring: applications and limitations. Sports Medicine 33, 517-538.
|
Ainsworth B.E., Haskell W.L., Whitt M.C., Irwin M.L., Swartz A.M., Strath S.J., O'Brien W.L., Bassett D.R., Schmitz K.H., Emplaincourt P.O., Jacobs D.R., Leon A.S. (2000) Compendium of physical activities: an update of activity codes and MET intensities. Medicine and Science in Sports and Eexercise 32, S498-504.
|
Astrand P.O., Ryhming I. (1954) A nomogram for calculation of aerobic capacity (physical fitness) from pulse rate during sub-maximal work. Journal of Applied Physiology 7, 218-221.
|
Bassett D.R., Ainsworth B.E., Swartz A.M. (2000) Validity of four motion sensors in measuring moderate intensity physical activity. Medicine and Science in Sports and Exercise 32, S471-S480.
|
Bouchard D.R., Trudeau F. (2008) Estimation of energy expenditure in a work environment: comparison of accelerometry and oxygen consumption/heart rate regression. Ergonomics 51, 663-670.
|
Brage S., Brage N., Franks P.W., Ekelund U., Wareham N.J. (2005) Reliability and validity of the combined heart rate and movement sensor Actiheart. European Journal of Clinical Nutrition 59, 561-570.
|
Corder K., Brage S., Ekelund U. (2007) Accelerometers and pedometers: methodology and clinical application. Current Opinion in Clinical Nutrition and Metabolic Care 10, 597-603.
|
Corder K., Brage S., Wareham N.J., Ekelund U. (2005) Comparison of PAEE from combined and separate heart rate and movement models in children. Medicine and Science in Sports and Exercise 37, 1761-1767.
|
Davidson L., McNeill G., Haggarty P., Smith J.S., Franklin M.F. (1997) Free-living energy expenditure of adult men assessed by continuous heart-rate monitoring and doubly-labelled water. The British Journal of Nutrition 78, 695-708.
|
Davis J.A., Vodak P., Wilmore J.H., Vodak J., Kurtz P. (1976) Anaerobic threshold and maximal aerobic power for three modes of exercise. Journal of Applied Physiology 41, 544-550.
|
Durnin J.V., Edwards R.G. (1955) Pulmonary ventilation as an index of energy expenditure. Quarterly Journal of Experimental Physiology and Cognate Medical Sciences 440, 370-377.
|
Ford A.B., Hellerstein H.K. (1959) Estimation of energy expenditure from pulmonary ventilation. Journal of Applied Physiology 14, 891-893.
|
Friedlander A.L., Jacobs K.A., Fattor J.A., Horning M.A., Hagobian T.A., Bauer T.A., Wolfel E.E., Brooks G.A. (2007) Contributions of working muscle to whole body lipid metabolism are altered by exercise intensity and training. American Journal of Physiology 292, E107-116.
|
Fruin M.L., Rankin J.W. (2004) Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Medicine and Science in Sports and Exercise 36, 1063-1069.
|
Garet M., Boudet G., Montaurier C., Vermorel M., Coudert J., Chamoux A. (2005) Estimating relative physical workload using heart rate monitoring: a validation by whole-body indirect calorimetry. European journal of applied physiology 94, 46-53.
|
Haskell W.L., Yee M.C., Evans A., Irby P.J. (1993) Simultaneous measurement of heart rate and body motion to quantitate physical activity. Medicine and Science in Sports and Exercise 25, 109-115.
|
Hiilloskorpi H.K., Pasanen M.E., Fogelholm M.G., Laukkanen R.M., Manttari A.T. (2003) Use of heart rate to predict energy expenditure from low to high activity levels. International Journal of Sports Medicine 24, 332-336.
|
King G.A., Torres N., Potter C., Brooks T.J., Coleman K.J. (2004) Comparison of activity monitors to estimate energy cost of treadmill exercise. Medicine and Science in Sports and Exercise 36, 1244-1251.
|
Kurpad A.V., Raj R., Maruthy K.N., Vaz M. (2006) A simple method of measuring total daily energy expenditure and physical activity level from the heart rate in adult men. European Journal of Clinical Nutrition 60, 32-40.
|
Livingstone M.B., Robson P.J., Totton M. (2000) Energy expenditure by heart rate in children: an evaluation of calibration techniques. Medicine and Science in Sports and Exercise 32, 1513-1519.
|
McCool F.D., Wang J., Ebi K.L. (2002) Tidal volume and respiratory timing derived from a portable ventilation monitor. Chest 122, 684-691.
|
Melanson E.L., Freedson P.S. (1996) Physical activity assessment: a review of methods. Critical Reviews in Food Science and Nutrition 36, 385-396.
|
Montoye H., Kemper H., Saris W. (1996) Measuring physical activity and energy expenditure. Human Kinetics.
|
Nilsson A., Brage S., Riddoch C., Anderssen S.A., Sardinha L.B., Wedderkopp N., Andersen L.B., Ekelund U. (2008) Comparison of equations for predicting energy expenditure from accelerometer counts in children. Scandinavian Journal of Medicine and Science in Sports 18, 643-650.
|
Plasqui G., Westerterp K.R. (2007) Physical activity assessment with accelerometers: an evaluation against doubly labeled water. Obesity (Silver Spring) 15, 2371-2379.
|
Ravussin E., Gautier J.F. (2002) Determinants and control of energy expenditure. Annales d'Endocrinologie 63, 96-105.
|
Rayson M.P., Davies A., Bell D.G., Rhodes-James E.S. (1995) Heart rate and oxygen uptake relationship: a comparison of loaded marching and running in women. European Journal of Applied Physiology and Occupational Physiology 71, 405-408.
|
Saltin B., Astrand P.O. (1967) Maximal oxygen uptake in athletes. Journal of Applied Physiology 23, 353-358.
|
Smith G.D., Morris J.N. (1992) Assessment of physical activity, and physical fitness, in population surveys. Journal of Epidemiology and Community Health 46, 89-91.
|
Spiro S.G. (1977) Exercise testing in clinical medicine. British Journal of Diseases of the Chest 771, 145-172.
|
Spurr G.B., Prentice A.M., Murgatroyd P.R., Goldberg G.R., Reina J.C., Christman N.T. (1988) Energy expenditure from minute-by-minute heart-rate recording: comparison with indirect calorimetry. The American Jjournal of Clinical Nutrition 48, 552-559.
|
Strange S., Secher N.H., Pawelczyk J.A., Karpakka J., Christensen N.J., Mitchell J.H., Saltin B. (1993) Neural control of cardiovascular responses and of ventilation during dynamic exercise in man. The Journal of Physiology 470, 693-704.
|
Swain D.P., Franklin B.A. (2006) Comparison of cardioprotective benefits of vigorous versus moderate intensity aerobic exercise. The American Journal of Cardiology 997, 141-147.
|
Taylor H.L, Buskirk E., Henschel A. (1955) Maximal oxygen intake as an objective measure of cardio-respiratory performance. Journal of Applied Physiology 8, 73-80.
|
Wasserman K., Beaver W.L., Whipp B.J. (1990) Gas exchange theory and the lactic acidosis (anaerobic) threshold. Circulation 81, II14-30.
|
Wasserman K., Whipp B., Casaburi R.., Fishman A., Cherniak N.S., Widdicombe J.G. (1986) Handbook of Physiology: The Respiratory System, a Control of Breathing. Respiratory control during exercise. Bethesda MD. Am. Physiol. Soc.
|
Westerterp K.R. (1999) Assessment of physical activity level in relation to obesity: current evidence and research issues. Medicine and Science in Sports and Exercise 31, S522-525.
|
Whipp B.J, Ward S.A. (1982) Cardiopulmonary coupling during exercise. The Journal of Experimental Biology 100, 175-193.
|
|
|
|
|
|
|